Aquifer and wells
How easily water moves through the full thickness of the aquifer. Clean sand is high; silt and clay are low.
Water released per unit area per metre of head drop. Confined aquifers are typically 10⁻⁵ to 10⁻³.
Cross-section
Drawdown at the observation point over time
How it works
- Theis equation (1935). For a well pumped at a constant rate Q in a confined aquifer, the drawdown s at distance r after time t is s = Q / (4πT) · W(u), with u = r²S / (4Tt). W(u) is the well function, W(u) = −0.5772 − ln u + u − u²/(2·2!) + u³/(3·3!) − …
- Cone of depression. Drawdown is largest at the well and falls with distance. The cone keeps widening as long as pumping continues.
- Radius of influence. The Cooper–Jacob approximation r0 = 1.5 √(T t / S) gives the distance at which the straight-line approximation of drawdown reaches zero. It is valid once u is small.
- Two wells. Drawdowns simply add (superposition): s = s1(r1) + s2(r2), where r1 and r2 are the distances to each well. The cross-section runs along the line through both wells.
The model assumes a confined, uniform, infinite aquifer of constant thickness, a fully penetrating well with negligible storage, and constant pumping, with no leakage or boundaries. Real Bangladesh aquifers are layered and leaky, so this explains the behaviour but must not be used to design or license a well. Drawdown shown is at the aquifer level; the vertical scale is exaggerated to make the cone visible.