New sample
| Parameter | Value | Limit | Level | Result |
|---|
Limits shown are the values built into this page. Standards are revised from time to time, so check them against the current official WHO or Department of Environment text before using a result in a report. Dissolved oxygen has no drinking-water health limit; the 5 mg/L (WHO column) and 6 mg/L (Bangladesh column) values are the usual WQI convention.
Saved samples 0
Samples are stored in this browser only. Export a CSV to keep or share them.
How the index is calculated
Weighted arithmetic WQI (Horton/Brown method). For each parameter measured: sub-index q = 100 × (V − Videal) / (S − Videal), where V is your reading, S the limit, and Videal is 0 (pH 7, dissolved oxygen 14.6 mg/L). Weight w = 1/S. WQI = Σ(q×w) / Σw, over the parameters you entered. For pH the deviation from 7 is used.
Classes: below 50 excellent, 50–100 good, 100–200 poor, 200–300 very poor, above 300 unsuitable for drinking. A WQI under 100 can still hide one parameter above its limit, which is why the table checks each one.