Vernier Caliper

Slide the object between the jaws and read the main scale and the vernier. Then switch to Practice and test your own reading.

Main scale reading
Vernier reading
Observed reading
After zero correction

Set up the caliper

Try this

  • In Explore mode, slide the object width slowly. Watch the vernier zero move along the main scale and the coinciding line shift one step each time.
  • Switch to LC 0.05 mm. The vernier has 20 divisions now, so the reading is twice as fine.
  • Set a zero error of +2 divisions. The jaws read a width even when closed, so the observed reading is too big. Subtract it.
  • Try Practice. Read the scales yourself, type the corrected reading, then press Check.

The equations

Least count = 1 main-scale division − 1 vernier division
LC = 1 mm / N,  with N vernier divisions equal to (N − 1) mm
Reading = MSR + (coinciding line × LC)
True reading = observed reading − zero error

A negative zero error (the vernier zero left of the main zero when closed) is subtracted too, so the correction is then added.