Noise with Distance

Predict how loud a construction site or plant will be at a nearby house. Set the machines, a barrier and the background level, then move the receptor and see where the day and night limits are met.

Site noise at the receptor
With background added
Day limit
Night limit

Describe the site

Drag the receptor on the graph, or use the slider. Measure the background first with the Sound Level Meter.

Try this

  • Double the distance from 100 m to 200 m. How many decibels do you lose? Try 400 m to 800 m.
  • Go from one machine to two. The level does not double. By how much does it rise, and from two to four?
  • Set the background to 55 dB in a residential zone. Can any distance meet the day limit? What does that tell you about the baseline?
  • Find the smallest barrier loss that lets a house at 150 m meet the night limit.

The equations

L₂ = L₁ − 20 log₁₀ (r₂ / r₁)
n equal sources: L = L₁ + 10 log₁₀ n
Adding levels: L = 10 log₁₀ (10La/10 + 10Lb/10)

This is the point-source rule for open, flat ground: 6 dB lost for each doubling of distance. It leaves out ground and air absorption, reflections, wind and the exact geometry of a barrier, so treat it as a first screening estimate. Limits shown are the dB(A) values in Bangladesh's Noise Pollution (Control) Rules 2006; check the current rules before quoting them in a report.